PRODUCT | Cable Ø | Cable Construction | C. B. L.* | C. B. L.* | C. B. L.* |
No. | mm | kN | kg | lb. | |
4.0*2 | 1×19 | 11.2 | 1,143 | 2,520 |
Cable length between fittings must be minimum 50 times cable diameter (Ø) for 1×19 construction.
* C. B. L. Characteristic Breaking Load, includes the typical 10% reduction in cable strength due to swaging.
*2 Imperial Cables – ex. North America only – loads stated are for typical Grade 316 Stainless Steel imperial cables, including 10% reduction in cable strength due to swaging. Final C. B. L. needs to be verified by imperial cable supplier.
Components
Compact Adjusters – Metric
Cable Ø | Thread | A | B | C Max | C Min | D | E | B. L. | Weight |
mm | mm | mm | mm | mm | mm | mm | kg | g | |
– | 1/4″ UNF | 7.0 | 9.0 | 147 | 117 | 11.0 | 6.2 | – | 80 |