PRODUCT | Cable Ø | Cable Construction | C. B. L.* | C. B. L.* | C. B. L.* |
No. | mm | kN | kg | lb. | |
9.5*2 | 1×19 | 59.3 | 6,042 | 13,320 |
Cable length between fittings must be minimum 50 times cable diameter (Ø) for 1×19 construction.
* C. B. L. Characteristic Breaking Load, includes the typical 10% reduction in cable strength due to swaging.
*2 Imperial Cables – ex. North America only – loads stated are for typical Grade 316 Stainless Steel imperial cables, including 10% reduction in cable strength due to swaging. Final C. B. L. needs to be verified by imperial cable supplier.
Components
Compact Adjusters
Cable Ø | Thread | A | B | C Max | C Min | D | E | B. L. | Weight |
mm | mm | mm | mm | mm | mm | mm | kg | g | |
9.5 | 5/8″ UNF | 18.0 | 22.2 | 308 | 258 | 30.0 | 15.7 | – | 1117 |