PRODUCT | Cable Ø | Turnbuckle Type | Cable Construction | C. B. L.* | C. B. L.* | C. B. L.* |
No. | in | kN | kg | lb. | ||
9/32 | Type 10 | 1 x 19 | 37.5 | 3,829 | 8,420 |
*C. B. L. = Characteristic Breaking Load; includes the typical 10% reduction in cable strength due to swaging
NOTE: Imperial Cables are available ex. North America only – Contact our North American office for full details.
Cable length between fittings must be minimum 50 times cable diameter (Ø) for 1×19 construction.
Components
Swage Toggles, Imperial Wire
Cable Ø | A | B | C | D | E | F | Weight |
in | in | in | in | in | in | in | oz |
9/32 | 0.563 | 0.688 | 2.875 | 5.969 | 1.156 | 0.500 | 11.4 |
Turnbuckles, Premium Closed Body, Toggle & Swage, Imperial Wire, Type 10
Cable Ø | Thread | A | B | C Max | C Min | D | E | Weight |
in | in | in | in | in | in | in | oz | |
9/32 | 1/2″ UNF | 0.531 | 0.688 | 16.938 | 12.563 | 1.125 | 0.500 | 25.6 |