PRODUCT | Cable Ø | Cable Construction | C. B. L.* | C. B. L.* | C. B. L.* |
No. | in. | kN | kg | lb. | |
0.866 | 1 x 19 | 359.9 | 27,330 | 60,252 |
*C.B.L.= Characteristic Breaking Load; includes the typical 10% redution in cable strength due to swaging
NOTE: Imperial Cables are available ex. North America only – Contact our North American office for full details.
Cable length between fittings must be minimum 50 times cable diameter (Ø) for 1×19 construction.
Components
Threaded Swage Terminals
Cable Ø | Thread | A | B | C | D | E | Weight |
in. | in. | in. | in. | in. | in. | oz. | |
0.866 | M36-4 | 1.417 | 9.606 | 21.693 | 9.921 | 1.563 | 147.7 |